Ir à oferta completa
INTERFACE 433MHZ
Descrição da oferta de emprego
433MHz Interface Design of a low-cost circuit with the following specifications.
5 negative digital inputs and 5 negative outputs, an input regulator supporting up to 36V, and a 433MHz receiver for remote control.
The circuit should include a hardware watchdog to reset in case of a system crash and must store up to 10 remote controls at 433MHz.
Inputs should be protected against positive voltages of up to 700V.
Additionally, a schematic and PCB layout are required.
All circuit development should be completed using the EasyEDA platform, where I will create the project and add your user account as a collaborator.
Components.
STM32 or PIC microcontrollers can be used.
Firmware.
Read digital inputs enabled by activating the alarm through the remote control.
Output 1 will be activated when the alarm is enabled through the remote control.
Output 2 will be triggered when input 1 is activated.
Output 3 will be triggered when input 2 is activated.
Output 4 will be activated when button 2 on the remote control is pressed.
If the alarm remains disabled for more than 3 hours, it will automatically reactivate.
The controls must be stored in the microcontroller’s EEPROM.
Layout PCB Eletrônica Engenharia Elétrica Microcontrolador Design de Circuito ID do Projeto.
# Sobre o projeto 13 propostas Aberto para ofertas Projeto remoto Ativo em 5 minutos atrás
5 negative digital inputs and 5 negative outputs, an input regulator supporting up to 36V, and a 433MHz receiver for remote control.
The circuit should include a hardware watchdog to reset in case of a system crash and must store up to 10 remote controls at 433MHz.
Inputs should be protected against positive voltages of up to 700V.
Additionally, a schematic and PCB layout are required.
All circuit development should be completed using the EasyEDA platform, where I will create the project and add your user account as a collaborator.
Components.
STM32 or PIC microcontrollers can be used.
Firmware.
Read digital inputs enabled by activating the alarm through the remote control.
Output 1 will be activated when the alarm is enabled through the remote control.
Output 2 will be triggered when input 1 is activated.
Output 3 will be triggered when input 2 is activated.
Output 4 will be activated when button 2 on the remote control is pressed.
If the alarm remains disabled for more than 3 hours, it will automatically reactivate.
The controls must be stored in the microcontroller’s EEPROM.
Layout PCB Eletrônica Engenharia Elétrica Microcontrolador Design de Circuito ID do Projeto.
# Sobre o projeto 13 propostas Aberto para ofertas Projeto remoto Ativo em 5 minutos atrás
Ir à oferta completa
Detalhes da oferta
Empresa
- Indeterminado
Localidade
- Em todo Portugal
Endereço
- Indeterminado - Indeterminado
Data de publicação
- 29/10/2024
Data de expiração
- 27/01/2025
Junior Functional Safety Engineer
Pixida
• creation of hazard analyses and risk assessments • development of reports and safety concepts with respect to iso 26262 • testing and validation in relation to functional safety requirements • definition and monitoring of development interface agreement (dia) as well as analysis of safety relevant......
STATUSQ APPS LLP
STATUSQ APPS LLP
Recognizing the importance of social media in today’s content landscape, statusq includes seamless integration with popular platforms like instagram, facebook, youtube, and tiktok... outros dados de posição statusq offers a wide range of professionally designed templates for users to choose from......